Vickers by Danfoss
02-353266
DG5V 7 2C 1 T M FTWL H5
This product has been discontinued.
The product is no longer available for purchase, but you can still find information about it, including service manuals, drawing etc.
Product specifications
Characteristic | Value |
---|---|
Actuation Identification | Solenoid A, Solenoid B |
Actuation Type | Pilot Operated |
Actuator Identification | Flag with Standard Build as Per ANSI B93 9 |
Application | Die casting & foundry, Machine tool, Marine/Offshore, Press, Primary metal, paper, Test equipment & simulation, Turbine control (wind, steam, water) |
Body material | Ductile Iron |
Brand | Vickers by Danfoss |
Build Orientation | Solenoid 'B' at port 'A' end of valve and Solenoid 'A' at port 'B' end of valve |
Build Type | Spring centered |
Coil Rating | 24 Volt DC |
Coil Type | 1/2 inch NPT thread conduit box |
Design code | 40 |
Electrical connector | Flying Lead Coil with 1/2 In. NPT Thread Wiring Housing |
Feature | Three- or four-way directional controlEasily mountable on industry-standard surfacesThousands of models to suit all applications |
Flow rate | 300 l/min |
Fluid Cleanliness | 19/17/14 micron |
Fluid compatibility | Petroleum Oils |
Function | Directional Control Valve |
Interface | ISO4401-07 |
Leakage | Standard |
Light | No |
Manual Override | Plain |
Model Code | DG5V 7 2C 1 T M FTWL H5 40 |
Pilot Drain | Internal |
Pressure Rating | 350 bar |
Product Height | 7.17 in |
Product Length/Depth | 8.7 in |
Product Type | Directional Control Valves |
Product Volume | 227.683 in³ |
Product Weight | 20 lb |
Product Width | 3.65 in |
Seal material | Buna-N |
Size | D07 |
Special features | None |
Spool Center Condition | A Port and Double Offset sensing switch on B Port |
Spool Monitor Switch | None |
Spring Arrangement | C |
Sub-brand | None |
Tank Port Rating | 100 bar |
Trade Name | DG5V-7 40 Design |
Valve Mount Type | Subplate/manifold mounted |
Wattage | 30 W |
Working temperature - max | 70 °C |
Working temperature - min | -20 °C |