Product specifications

Characteristic
Value
Description
F: NOT USED0NOT APPLICABLE
G: END CAP81 inch Twin Ports, 6000 PSI
H: LOOP FLUSHING TYPEWWith Loop Flushing Valve
J: NOT USEDNNot Applicable
K: CHARGE PRS RLF AMSN6Loop Flushing Flow 7 l/min at 25 bar, Cracking Pressure 13 bar, Orifice 1x1,5 mm
L: SHAFTC3splined shaft , 15 teeth, pitch = 16 / 32
M: NOT USEDNCNOT APPLICABLE
N: NOT USEDNNOT APPLICABLE
P: PRESSURE REGULATION0No High Pressure Regulation
Series 90 Displacement04242 Cubic Centimeters per Revolution
Series 90 Flange Style MFMFixed Motor, SAE Flange
Series 90 Product Line90Series 90
T: NOT USED00NOT APPLICABLE
W: SPECIAL HARDWARE FEATUREEFASpeed Sensor, Turck Connector, 4.5-8.5V, Direction Sensing, KPPx136
Y: HIGH PRS SETTING PORT A00Pressure Settings Not Adjusted
Z: HIGH PRS SETTING PORT B00Pressure Settings Not Adjusted

General specifications

Characteristic
Value
Proposition 65Cancer and Reproductive Harm