Vickers by Danfoss VLE Priority Valves 606-1095-003-KB [RIGHT]

VLEA03B44P0B

606-1356-003-WA


Tools

Product specifications

Characteristic
Value
BrandVickers by Danfoss
Control_spring6.9 BAR [100 PSI]
Customer_IdentificationDanfoss, painted black
Design_codeSecond
Inlet_flow_rating151 LPM [40 GPM]
Metering_typeStandard
Pilot_signalLOAD SENSING PILOT ONLY - DYNAMIC
Port_sizesCF M18x1.5, P & EF M27x2
Pressure_Setting242 BAR / 3500 PSI
Product_seriesValve
Product_typeEXTERNAL PILOT OPERATED FLOW CONTROL (PRIORITY) VALVE
Relief_dashpot0.67mm [.0265] DIA (STD. WITH INVERTED RELIEF VALVE)
Relief_valveINVERTED STYLE 276 BAR [4000 PSI] – LIMIT
Special_feataureDS - 0.61 [.024] DIA LS – 0.91[.036] DIA PP – 0.91[.036] DIA