Product specifications
Characteristic | Value |
---|---|
Adjustment type | Cap |
Brand | Vickers by Danfoss |
Cavity | C-12-3S |
Flow rate LPM | 114.00 |
Fluid compatibility | MIL-H-5606, SAE10, SAE20, etc |
Function | Counterbalance Valve |
Housing | Yes |
Housing material | Aluminum |
Installation type | Screw-in Cartridge |
Leakage | 0.25 cc/min |
Max load induced p BAR | 350.000 |
Max pilot adjust p BAR | 37.400 |
Max relief press BAR | 350.000 |
Min pilot adjust p BAR | 30.600 |
Model Code 1 | CBV1-12-C-I-A-4G-A-30-XXX |
Number of housing ports | 3 |
Number of valve ports | 3 |
Operating temperature | -40 C to 120 C (-40 to 248 F) |
Operation | Pilot operated |
Pilot ratio | 4:1 |
Port Size | 1/2" |
Port type | BSPP |
Pressure rating BAR | 350 |
Recommended filtration level | 18/16/13 |
Seal type | Nitrile |
Special features | None |
Style | 3-Ported, Externally Piloted |
Valve torque into cavity | 81–95 Nm |