Vickers by Danfoss KBHDG5V-7 12 Design Proportional Valves with OBE KBHDG5V-7-2C150N85-EX-M1-PE7-H4-12 (RIGHT)

KBHDG5V-7-2C150N85-EX-M2-PE7-H4-12-EN118, KBHDG5V72C150N85EXM212EN118

864AN00101A

Model code: KBHDG5V72C150N85EXM212EN118

Recommended replacement: 864AN00186A


Tools

Product specifications

Characteristic
Value
A Port flow LPM150.00
A Port flow USGPM39.60
Actuation TypeSolenoid controlled pilot operated
B Port flow LPM85.00
B Port flow USGPM22.50
BrandVickers by Danfoss
Build orientationSolenoid at B port end
Build typeSpring centered
Coil voltage24 Volt DC
Command input4-20mA Command +/-10V feedback
Communication protocolNone
Current3 amp
Design series12 Series
Electrical ConnectionElectrical (PE7) 7 pin electrical plug with mating half
Feedback sensorYes
Fluid cleanliness17/15/12 micron
Fluid compatibilityAntiwear hydraulic oils and non alkyl-based Phosphate Esters
InterfaceISO4401-07/NFPA D07/CETOP 7/NG16
Manual overrideNone
Maximum pressure BAR350
Maximum pressure PSI5000
MeteringMeter in / meter out
Model Code 1KBHDG5V72C150N85EXM212EN118
On board electronicsYes
PerformanceServo
Pilot drainExternal
Pilot supplyExternal
Product height in9.870
Product height mm250.698
Product length in10.920
Product length mm277.368
Product width in3.620
Product width mm91.948
ProFX compatibleNo
Reducer moduleYes
Reverse flow checkNo
Seal typeViton
Special featuresStrengthened anti-rotation pin
Spool TypeISO4401-10/NFPA D10/CETOP 10/NG32
StageTwo stage
Symmetric flowNo
Tank port rating BAR350
Tank port rating PSI5000
Valve Mount TypeSubplate
Valve TypeProportional directional
Working temp max C70
Working temp max F158
Working temp min C-40
Working temp min F-40