Product specifications
Characteristic | Value | Description |
---|---|---|
100% step response | 8 ms | |
Brand | Vickers by Danfoss | |
Burst pressure return | 250 (% max supply pressure) | |
Coil rated current | 40 mA | |
Coil resistance | 80 Ohms | |
Design series | 10 Series | |
Flow rating GPM | 5.00 | |
Flow rating LPM | 19.0 | |
Frequency response @-3dB | 110 Hz | |
Frequncy response @ 90° | 150 Hz | |
Hysteresis around null | </= 3 (% of rated current) | |
Linearity error | <10 (% of rated current) | |
Maximum supply pressure BAR | 200 | |
Maximum supply pressure PSI | 3000 | |
Minimum supply pressure BAR | 14 | |
Minimum supply pressure PSI | 200 | |
Model Code 1 | SM410(5)1980/4010 | |
Port circle inch | 0.625 | |
Proof pressure return | 100 (% max supply pressure) | |
Proof pressure supply | 150 (% max supply pressure) | |
Series | SM4 | |
Special feature | NN | None |
Symmetry error | <10 (% of rated current) | |
Threshold | </= 0.5 (% of rated current) | |
Valve size | Size 10 | |
Working temp max C | 135 | |
Working temp max F | 275 |