Product specifications
Characteristic | Value | Description |
---|---|---|
A Port flow LPM | 550.00 | |
A Port flow USGPM | 145.00 | |
Actuation Type | Solenoid contr. pilot operated | |
B Port flow LPM | 550.00 | |
B Port flow USGPM | 145.00 | |
Brand | Vickers by Danfoss | |
Build orientation | Standard as per ANSI B93 9 | |
Build type | Spring centered | |
Coil voltage | 24 Volt DC | |
Command input | +/- 10V control signal | |
Communication protocol | None | |
Design Series | 12 Series | |
Electrical Connection | 7 Pin connector without plug | |
Feedback sensor | No | |
Fluid Cleanliness | 17/15/12 micron | |
Fluid compatibility | Antiwear hydraulic oils | |
Interface | ISO4401-10/NFPA D10/CETOP 10 | |
Manual override | Plain | |
Maximum pressure BAR | 350 | |
Maximum pressure PSI | 5000 | |
Metering | Meter in / meter out | |
Model Code 1 | KBDG5V1033C550NXM1PC7H112 | |
On board electronics | Yes | |
Performance | Standard | |
Pilot drain | External | |
Pilot supply | Internal | |
ProFX compatible | No | |
Reducer module | Yes | |
Reverse flow check | No | |
Seal type | Viton | |
Special features | None | |
Spool Type | P blocked, A & B to tank | |
Stage | Two stage | |
Symmetric flow | Yes | |
Tank port rating BAR | 350 | |
Tank port rating PSI | 5000 | |
Valve Mount Type | Subplate | |
Valve Type | Proportional directional | |
Working temp max C | 70 | |
Working temp max F | 158 | |
Working temp min C | -20 | |
Working temp min F | -4 |