Product specifications
Characteristic | Value |
---|---|
Actuation type | Pilot operated |
Brand | Vickers by Danfoss |
Coil Rating | 110 VAC 50Hz/120 VAC 60Hz |
Design series | 10 Series |
Electrical connection | Flying lead 1/2" NPT housing |
Ext pilot pressure | External |
Flow rate upto GPM | 185.0 |
Flow rate upto LPM | 700.0 |
Fluid cleanliness | 19/17/14 micron |
Fluid compatibility | Petroleum oils |
Gauge port thread type | 0.4375 - 20 UNF, SAE Thread |
Indicator light | No |
Int pilot drain | External |
Interface | ISO4401-08 |
Manual override | Plain |
Model Code | DG5V8H4CEVMFWB10 |
Performance | High performance |
Power Consumption | 49VA 50HZ - 48VA 60HZ |
Pressure ratiing PSI | 5000 |
Pressure rating BAR | 350 |
Seal type | Buna-N |
Solenoid Energising ID | Sol A port A/Sol B port B |
Special features | None |
Spool Position Monitor | No |
Spool type | Spool 4 |
Spring arrangement | Spring centred |
Stage | Two stage |
Surge Suppr Damper | No |
Tank port rating BAR | 350 |
Tank port rating PSI | 5000 |
Valve mount type | Subplate/manifold mounted |
Valve type | Directional control valve |
Working temp max C | 65 |
Working temp max F | 150 |
Working temp min C | -20 |
Working temp min F | -4 |