Danfoss logo
Vickers by Danfoss DG4S4-01 60 Design Directional Control Valves Single Stage PA5DG4S4W016BB60 (RIGHT)

PM4DG4S4LW-016C-H-60-S60 7, PM4DG4S4LW016CH60S607

02-394267

Model code: PM4DG4S4LW016CH60S607


Tools

Product specifications

Characteristic
Value
Description
Actuation typeSOLENOID OPERATEDSolenoid operated
BrandVICKERS BY DANFOSSVickers by Danfoss
Coil Rating24 VDC24 VDC
Design Series60 SERIES60 Series
Electrical connection4-PIN CONNECTOR4-pin connector
Energ Time50-80 MS50-80 ms
Flow rate upto GPM25.0
Flow rate upto LPM95.0
Fluid cleanliness20/18/15 MICRON20/18/15 micron
Fluid compatibilityPETROLEUM OILSPetroleum oils
Indicator lightYESYes
InterfaceISO4401-05ISO4401-05
Manual overrideNONENone
Model Code 1PM4DG4S4LW016CH60S607
PerformanceSTANDARD PERFORMANCEStandard performance
Pressure rating Bar250
Pressure rating PSI3600
Product height in3.850
Product length in6.840
Product length mm173.736
Product width in2.810
Product width mm71.374 mm
Seal typeBUNA-NBuna-N
Solenoid Energising IDSTANDARD AS PER ANSI B93 9Standard as per ANSI B93 9
Special featuresWIRED TO AUTOMOTIVE STANDARDWired to automotive standard wiring scheme, terminal strip and push in lights
Spool Position MonitorNONo
Spool TypeSPOOL 6Spool 6
Spring arrangementSPRING CENTRED, THREE POSITIONSpring centred, three position
StageSINGLE STAGESingle stage
Surge Suppr DamperNONo
Tank port rating BAR70
Tank port rating PSI1000
Valve mount typeSUBPLATE/MANIFOLD MOUNTEDSubplate/manifold mounted
Valve typeDIRECTIONAL CONTROL VALVEDirectional control valve
Working temp max C50
Working temp max F122
Working temp min C20