Danfoss logo
Vickers by Danfoss DG4V-3 60 Design Directional Control Valves Single Stage DG4V30BLMFPM4WLD7H760EN623 (RIGHT)

DG4V-3-0BL-M-FPM4WL-D7-H7-60-EN623, DG4V30BLMFPM4WLD7H760EN623

02-394757


Tools

Product specifications

Characteristic
Value
Actuation TypeSolenoid operated
BrandVickers by Danfoss
Coil Rating24 VDC
Design Series60 Series
Electrical Connection4-Pin Brad Harrison connector
Energ Time45-28 ms
Flow rate upto GPM21.0
Flow rate upto LPM80.0
Fluid Cleanliness19/17/14 micron
Fluid compatibilityPetroleum oils
Indicator LightYes
InterfaceISO4401-03
Manual overridePlain
Model codeDG4V30BLMFPM4WLD7H760EN623
PerformanceHigh performance
Power Consumption30 watt
Pressure rating BAR350
Pressure rating PSI5000
SEAL TYPEViton
Solenoid Energising IDStandard as per ANSI B93 9
Special featuresWired To Automotive Standard
Spool Position MonitorNo
Spool TypeSpool 0
Spring ArrangementSpring offset end to centre LH
StageSingle stage
Surge Suppr DamperYes
Tank port rating BAR210
Tank port rating PSI3000
Valve Mount TypeSubplate/manifold mounted
Valve TypeDirectional control valve
Working temp max C70
Working temp max F158
Working temp min C-20
Working temp min F-4