Danfoss logo
Vickers by Danfoss DG5V-8 10 Design Directional Control Valves Two Stage 836AN00274A (RIGHT)

DG5V-8-H-8C-2-S-VM-U-C-10, DG5V8H8C2SVMUC10

02-399086

Model code: DG5V8H8C2SVMUC10


Tools

Product specifications

Characteristic
Value
Description
Actuation TypePILOT OPERATEDPilot operated
BrandVICKERS BY DANFOSSVickers by Danfoss
Coil Rating220 VAC 50HZ220 VAC 50Hz
Design Series10 SERIES10 Series
Electrical ConnectionISO 4400 (DIN 43650) CONNECTORISO 4400 (Din 43650) connector
Ext pilot pressureINTERNALInternal
Flow rate upto GPM185.0
Flow rate upto LPM700.0
Fluid Cleanliness19/17/14 MICRON19/17/14 micron
Fluid CompatibilityPETROLEUM OILSPetroleum oils
Gauge Port Thread Type0.4375 - 20 UNF, SAE THREAD0.4375 - 20 UNF, SAE Thread
Indicator LightNONo
Int pilot drainEXTERNALExternal
InterfaceISO4401-08ISO4401-08
Manual overridePLAINPlain
Model Code 1DG5V8H8C2SVMUC10
PerformanceHIGH PERFORMANCEHigh performance
Power Consumption49 VA49 VA
Pressure rating BAR350
Pressure rating PSI5000
Product height in9.360
Product height mm237.744
Product length in10.450
Product length mm265.430
Product width in4.670
Product width mm118.618 mm
Seal TypeBUNA-NBuna-N
Solenoid Energising IDSOL A PORT A/SOL B PORT BSol A port A/Sol B port B
Special FeaturesNONENone
Spool ControlPILOT CHOKE ADJUSTMENTPilot choke adjustment
Spool Position MonitorNONo
Spool TypeSPOOL 8Spool 8
Spring ArrangementSPRING CENTREDSpring centred
StageTWO STAGETwo stage
Surge Suppr DamperNONo
Tank port rating BAR350
Tank port rating PSI5000
Valve Mount TypeSUBPLATE/MANIFOLD MOUNTEDSubplate/manifold mounted
Valve TypeDIRECTIONAL CONTROL VALVEDirectional control valve
Working temp max C65
Working temp max F150
Working temp min C-20
Working temp min F-4