Product specifications
Characteristic | Value | Description |
---|---|---|
Actuation Type | Pilot operated | |
Adjustment range bar | 140 | |
Adjustment range PSI | 2000 | |
Adjustment type | Screw with locknut | |
Brand | Vickers by Danfoss | |
Check valve | No | |
Design Series | 30 Series | |
Electrical connection | None | |
Flow rate LPM | 265 | |
Flow rate USgpm | 70.0 | |
Fluid Cleanliness | 19/17/14 micron | |
Fluid compatibility | Petroleum oils | |
Gauge port thread | 1/4 NPTF | |
Hi-vent spring | No | |
Indicator Light | No | |
Maximum pressure BAR | 210 | |
Maximum pressure PSI | 3000 | |
Model Code 1 | XGH06230 | |
Performance | Standard | |
Seal material | Nitrile | |
Size | Size 06 | |
Special feature | NN | None |
Stage | Two stage | |
Valve Mount Type | Subplate/manifold mounted | |
Valve type | Pressure reducing valve | |
Working temperature max C | 70 | |
Working temperature max F | 158 | |
Working temperature min C | -20 | |
Working temperature min F | -4 |