Vickers by Danfoss KBFDG5V-10 10 Design Proportional Valves with OBE KBFDG5V-10-34C700N-X-M1-PE7-H1-10 (RIGHT)

KBFDG5V-10-33C700N-EX-M1-PC7-H1-10

5992991-001

Recommended replacement: 861AN00043A


Tools

Product specifications

Characteristic
Value
A Port flow LPM700.00
A Port flow USGPM185.00
Actuation TypeSolenoid controlled pilot operated
B Port flow LPM700.00
B Port flow USGPM185.00
BrandVickers by Danfoss
Build orientationSolenoid 'B' at port 'A' end of valve and solenoid 'A' at port 'B' end of valve
Build typeSpring centered
Coil voltage24 Volt DC
Command input+/-10V Command +/- 10V feedback
Communication protocolNone
Current1.6 amp
Design Series10 Series
Electrical ConnectionElectrical (PC7) 7 pin connector without plug
Feedback sensorYes
Fluid Cleanliness17/15/12 micron
Fluid compatibilityAntiwear hydraulic oils and non alkyl-based Phosphate Esters
InterfaceISO4401-10/NFPA D10/CETOP 10
Manual overrideNone
MeteringMeter in / meter out
On board electronicsYes
PerformanceHigh
Pilot drainExternal
Pilot supplyExternal
Pressure drop rated flow BAR5
Pressure drop rated flow PSI72
Pressure rating BAR350
Pressure rating PSI5000.00
ProFX compatibleNo
Reducer moduleYes
Seal typeFluorocarbon
Special featuresNone
Spool TypeBleed A and B to T
StageTwo stage
Symmetric flowYes
Tank port rating BAR350
Tank port rating PSI5000
Valve Mount TypeSubplate
Valve TypeProportional directional
Working temp max C70
Working temp max F158
Working temp min C-20
Working temp min F-4